← raulsosa.co System model · Public sources

SysML v2 · Advanced Nuclear

ZettaJoule ZJ0 — Reactor & Plant System Model

A model-based read of a 30 MWth high-temperature gas-cooled reactor: what the plant must do, how it decomposes, how it moves between operating states, and how the heat path is wired. Built from public ZettaJoule material and the documented HTTR reference plant.

Independent public-source model — not ZettaJoule documentation. ZettaJoule publishes no system design descriptions, P&IDs, or safety analysis. Everything here is reconstructed from their public statements plus the openly documented HTTR design (JAERI-1332, IAEA-TECDOC-1236/1382). Tags mark provenance: S stated in a source · D derived from sources · A assumption / inference.

From documents to models The method behind this model: how a document-centric engineering group moves to MBSE.

ZJ0 System Model Explorer

Four views, one model · requirements, decomposition, behaviour, interfaces

req [Package] ZJ0_Requirements [Baseline v0.1]
«requirement» Stakeholder S
SR-00 — Deliver 30 MWth of process heat at up to 950 °C
id: SR-00 · verification: analysis
«requirement» Functional S
FR-01 — Control reactivity without operator action
id: FR-01
verification: test
«requirement» Functional S
FR-02 — Remove residual heat with forced flow lost
id: FR-02
verification: test
«requirement» Functional S
FR-03 — Confine fission products across four barriers
id: FR-03
verification: analysis
«requirement» Functional S
FR-04 — Transfer process heat at 950 °C
id: FR-04
verification: analysis
«requirement» Derived S
DR-01 — Fuel ≤ 1600 °C in any accident
id: DR-01 · parent: FR-01
«requirement» Derived S
DR-02 — VCS removes ≥ 0.3 MW with no forced cooling
id: DR-02 · parent: FR-02
«requirement» Derived D
DR-03 — Containment leak ≤ 0.1 %/day
id: DR-03 · parent: FR-03
«requirement» Derived S
DR-04 — IHX ≥ 10 MW at 955 °C tube design
id: DR-04 · parent: FR-04
«block» A1 S
Core & Internals
+ satisfies DR-01
«block» D2 S
Vessel Cooling System
+ satisfies DR-02
«block» E1 D
Containment Vessel
+ satisfies DR-03
«block» B3 S
Intermediate Heat Exchanger
+ satisfies DR-04

Scroll sideways to see the whole diagram.

«contain» — requirement hierarchy «derive» — derived requirement «satisfy» — block meets requirement S sourced · D derived · A assumed
bdd [Package] ZJ0_PlantDecomposition [Level 0–1]
«block» Plant S
ZJ0 Plant — 30 MWth HTGR
+ licensable unit: 1
+ outlet: 950 °C
«block» A · Reactor Island S
Reactor Island
+ A1 Core & internals
+ A2 Pressure vessel
+ A3 Reactivity control
+ A4 Nuclear instrumentation
«block» B · Heat Transport S
Primary Heat Transport
+ B1 Helium circulators
+ B2 Hot gas duct
+ B3 Intermediate HX
+ B5 Purification
«block» C · Heat Utilization D
Heat Utilization & Conversion
+ C1 Secondary helium loop
+ C2 Process interface
+ C5 Pressurized water cooler
+ C4 Air cooler
«block» D · Safety S
Residual Heat & Protection
+ D1 Auxiliary cooling
+ D2 Vessel cooling (2 trains)
+ D3 Reactor protection
+ D6 Emergency power
«block» E · Confinement A
Confinement & Civil
+ E1 Containment vessel
+ E3 Reactor building
+ E4 Biological shielding
+ E8 HVAC
«block» F/G/H/K · Infrastructure D
I&C, Electrical, Fuel & Site
+ F Digital I&C
+ G Power systems
+ H Refueling & storage
+ K Site & BOP

Scroll sideways to see the whole diagram.

«contain» — composition Level 1 domains carry their Level 2 subsystems as properties S sourced · D derived · A assumed
stm [StateMachine] ZJ0_OperatingModes [Normal + LOFC]
«state» S
Cold Shutdown
T < 100 °C
«state» S
Heatup
purity & leak checks
«state» S
Hot Standby
critical, low power
«state» S
Rated Operation 850 °C
30 MWth
«state» S
High-Temperature Test 950 °C
test permit required
«state» S
Refueling
core access
«state» S
Shutdown Cooling
forced, ACS / VCS
«state» S
LOFC / ATWS
circulators tripped
rods blocked
«state» S
Self-Stabilized Low Power
~1.2 % power
fuel < 1600 °C
«state» final S
Cooldown to Cold Shutdown
residual heat to VCS

Scroll sideways to see the whole diagram.

transition — label is the guard condition The LOFC branch is the one the HTTR demonstrated at 100 % power in March 2024 S sourced · D derived · A assumed
ibd [Block] ZJ0_Plant [Primary Heat Path]
«block» A1 S
Core & Internals
+ fuel: TRISO prismatic
+ 30 columns
«block» A2 S
Reactor Pressure Vessel
+ 2.25Cr-1Mo steel
+ 4 MPa helium
«block» B2 S
Hot Gas Duct
+ concentric
+ inner liner insulated
«block» B3 A
Intermediate Heat Exchanger
+ tubes: Hastelloy XR
+ duty > 10 MW †
«block» C1 S
Secondary Helium Loop
+ pressure > primary
+ process heat out
«block» B1 S
Helium Circulators
+ 3 units (HTTR)
+ variable speed
«block» D2 S
Vessel Cooling System
+ 2 independent trains
+ ≥ 0.3 MW residual
«block» D1 S
Auxiliary Cooling System
+ AHX ~3.5 MW
+ 2 aux circulators
«block» C5 S
Pressurized Water Cooler
+ 3.5 MPa water
+ 20 MW in parallel
«block» C4 S
Air Cooler
+ ultimate heat sink
+ to atmosphere

Scroll sideways to see the whole diagram.

connector — labelled with medium and condition † ZettaJoule states the IHX is enlarged over HTTR's 10 MW; exact duty is not published S sourced · D derived · A assumed

What is sourced

Plant type, power, outlet temperature, fuel form, coolant, IHX material, VCS function, and the LOFC behaviour all appear in ZettaJoule material or the HTTR design record.

  • JAERI-1332 — HTTR design report
  • IAEA-TECDOC-1236 and 1382
  • JAEA 2024 loss-of-forced-cooling test

What is inferred

ZettaJoule publishes no system design descriptions, P&IDs, setpoints, or safety analysis. Any element tagged A is an engineering inference from the reactor class, not a published value.

  • ZJ0 retaining a containment vessel
  • IHX duty above 10 MW
  • Exact subsystem boundaries

Why the model separates configurations

The ZJ0 research reactor and the commercial ZJ are not the same plant. The commercial design removes the containment vessel, lowers some safety classifications, moves to digital I&C, and adds a helium gas turbine.

This page models ZJ0 only. Mixing the two would produce a plant that does not exist.